A 600 MW-class expander for compressed air energy storage (CAES) systems, jointly developed by the Institute of Engineering Thermophysics (IET) of the Chinese Academy of Sciences and China Energy Storage National Power (中儲国能), has been completed. An expander is a device that uses the force of compressed air expanding to drive a generator. According to a China Central Television (CCTV) report published by the Chinese Academy of Sciences dated November 25, 2026, the unit has completed integrated and mechanical testing, and all test results met or exceeded design targets.
This year in China, the 600 MW-class Huai'an power plant, which has two 300 MW-class generating units, came fully online. The newly completed expander is intended for a system with an output scale equivalent to that entire plant. In power generation using compressed air, the pressure inside the storage facility falls as air is drawn out. A key technical challenge is therefore maintaining the required output and high generating efficiency even as the conditions of the air supplied to the expander change.
From 300 MW-class to 600 MW-class: scaling up core equipment
At the power plant in Huai'an, Jiangsu Province, Unit 1 was first connected to the grid in July 2025 and reached full 300 MW load operation in December of that year. Unit 2 was also connected to the grid and reached full-load operation in January 2026, meaning the whole plant is now operating, as we reported in an earlier article (Japanese).
The Huai'an plant secures a combined 600 MW-class output from two 300 MW-class generating units and has an energy storage capacity of 2,400 MWh. MW is a measure of power, while MWh is a measure of energy. Based on the specifications published by State Xin Group (posted by the Jiangsu Provincial State-owned Assets Supervision and Administration Commission), 2,400 MWh ÷ 600 MW = 4 hours, meaning it can supply power at rated output for about four hours. Actual generating time varies with operating conditions.
The 600 MW-class figure for this latest development, by contrast, refers to the output scale of the system the new expander is designed for. IET and China Energy Storage National Power completed integrated testing of a 300 MW-class expander in early August 2023. At that time, IET's announcement also cited maintaining high efficiency across a wide range of operating conditions while handling large volumes of air as a technical challenge. After equipment testing, installation at a power plant and connection to the grid still lie ahead. The demonstration plant in Feicheng, Shandong Province, for which IET led technology development, was first connected to the grid in April 2024, the year after its equipment testing, according to the institute's report.
Handling the pressure drop in stored air
CAES is a technology that uses electricity to compress air and stores it at high pressure. When power is needed, the compressed air is released to spin an expander and generate electricity. Because compressing air produces heat, some systems store this heat of compression and reuse it to heat the air during generation. By storing both compressed air and heat, the system efficiently recovers the energy put into it. In Japan, the Institute of Applied Energy, NEDO, Waseda University and others also described a demonstration facility that recovers heat of compression in a joint 2017 announcement.
However, when air is drawn from a constant-volume storage space, the internal pressure gradually falls. If the expander's inlet pressure changes, the air flow rate and expansion ratio also change, moving away from the operating conditions assumed at the design stage. Reducing the pressure with an inlet control valve and feeding air to the expander at a constant pressure makes it easier to stabilize output, but some of the energy that could otherwise be used for generation is lost in the process. This is called "throttling loss." According to a research paper by Pan et al., adjusting operating conditions to match pressure changes can reduce this loss, but it demands that the expander handle a wide range of operating conditions.
In this paper, published in the journal Energy, simulations were carried out on a 300 MW-class system developed by IET. The research team examined performance when a pre-expander installed upstream of the main expander was combined with a bypass flow path to divert air, with rotational speed and other parameters adjusted. They computed performance by numerically simulating airflow inside the expander and built the results into a system model that reproduces pressure and temperature changes during operation.
Under conditions that held the main expander's aerodynamic output constant, aerodynamic work over the whole discharge period increased by 6.54% with a fixed-speed configuration and by 6.69% with a configuration optimized by varying rotational speed, compared with a configuration using only the main expander. Both configurations were equipped with a pre-expander and a bypass flow path, and the difference between the two corresponds to the effect of adjusting rotational speed. The figures calculated here are simulated values for the mechanical energy that can be extracted from compressed air in a single discharge.
According to CCTV, the design challenge for this 600 MW-class expander was likewise maintaining high efficiency across a wide output range while varying rotational speed. The development team spent about two years on design that accounts for three-dimensional airflow under various operating conditions and on the structural design of the long shaft system that comes with a multistage configuration, and says it developed technology for adjusting flow path geometry and rotational speed in combination.
Cost per unit of output down 20–30%, system efficiency up 3–5%
CCTV reported, citing the developers, that compared with a 300 MW-class system, cost per unit of output would fall by 20–30% and system efficiency would improve by 3–5%. Cost per unit of output is a metric showing how much it costs relative to a facility's generating capacity. To assess the cost per unit of electricity actually delivered, it is necessary to consider not only construction and maintenance costs but also the amount of electricity obtained through repeated charge and discharge cycles.
The published reports do not disclose which equipment and expenses are included in the cost calculation, or the absolute efficiency of the system used as a comparison. It is also unclear whether the 3–5% efficiency improvement is a relative increase or a gain in percentage points. The report also does not disclose load-by-load performance curves, test duration, or which power plant will adopt the new expander and with what storage capacity.
At an actual power plant, the required output changes with power demand even as the pressure of the stored air falls. To evaluate the economics of the equipment, therefore, it matters not only what the peak efficiency is, but how much efficiency can be maintained, and for how long, under various pressure and load conditions.
Underground salt caverns and thermal storage support large-scale energy storage
The Huai'an plant uses a cavern in a salt layer about 1,350 m underground to store compressed air. The cavern has a volume of about 1 million m³, and State Xin Group has published a storage pressure of up to 17 MPa. For heat storage, it uses a combination of molten salt and pressurized heat-transfer water, with a storage temperature said to reach 360°C. According to the group, Unit 2 of the Huai'an plant carried out 68 complete charge-discharge cycles during the peak power demand period in summer 2026.
At the 300 MW-class demonstration plant in Yingcheng, Hubei Province, the design of the underground storage facility was also a key challenge. According to a report by the Institute of Rock and Soil Mechanics of the Chinese Academy of Sciences, the plant achieved grid connection at full output on January 9, 2025, and began injecting air into and withdrawing it from two underground caverns. The published energy storage capacity is 1,500 MWh, with a discharge time of 5 hours. Drilling large-diameter wells linking the underground caverns to the surface generating equipment, so that the required volume of air could be moved in and out for power generation, was also a development challenge.
At Yingcheng, the shape of caverns formed in a layered salt formation and the handling of sediment accumulated at the bottom posed problems. The research team developed a method to determine the cavern's shape and the gas-liquid interface and to use the gaps in the sediment for compressed air storage as well. Through field tests and other work, it says it raised the utilization rate of the underground space from 20% to over 70%. To supply enough compressed air to a high-output expander, the effective volume of such underground space and the air flow rate that can be delivered through the wells are also important.
In its explanation of policy for the 15th Five-Year Plan period, published on November 13, China's National Energy Administration set out a policy of promoting the commercial use of compressed air energy storage. Standardization of equipment performance evaluation and test methods is also moving forward. A draft national standard for power plant expanders, whose drafting IET led, passed review in August 2026, including performance indicators and test requirements, according to the institute's report.
For the newly developed 600 MW-class expander, part-load efficiency, start-up and shutdown characteristics, and charge-discharge track records in combination with underground storage and thermal storage facilities will be the materials for future evaluation. To realize the cost savings from larger expanders at actual power plants, the design of the entire system, one that can stably supply the required amounts of compressed air and heat while responding to changing pressure and power demand, is essential.