A research team at the Okinawa Institute of Science and Technology Graduate University (OIST), including Morihiro Ota, Ching-Ping Lee and Yuimaru Kubo, has used synthetic diamond to amplify weak microwave signals by a power ratio of more than 1,000. The team built a "maser" amplifier that operates at temperatures close to absolute zero, achieving a power gain above 30 dB and an amplification bandwidth of about 70 kHz for a 6.595 GHz signal. The results were published on November 16, 2026, in the peer-reviewed journal Nature Communications (volume 17, article number 11458).
The device is expected to enable low-noise amplification in magnetic fields, which is needed for reading out semiconductor spin qubits and similar devices. The team measured not only the amplification performance but also the noise the amplifier adds to the signal and the conditions under which strong input signals reduce its gain, clarifying both the performance and the remaining challenges for quantum-device applications.
How Nitrogen in Diamond Amplifies Microwaves
A maser amplifies microwaves using the same principle of "stimulated emission" as a laser. Whereas lasers mainly handle visible and other light, masers handle microwaves, which have lower frequencies. The technology was developed in the 1950s, but its uses have been limited, partly because it requires extremely low temperatures. Now that quantum computers themselves operate at cryogenic temperatures, masers are drawing renewed attention as a way to amplify faint signals in the same environment.
The amplification in this study is carried out by the electron spins of "P1 centers," nitrogen impurities that replace carbon atoms in the diamond crystal. The experiment used a synthetic diamond crystal measuring 3 mm by 1.5 mm by 0.5 mm. The crystal contains about 16 ppm of P1 centers and about 2 ppm of negatively charged nitrogen-vacancy (NV⁻) centers. The electron spins of the P1 centers are the ones directly involved in amplifying the microwaves.
The team placed the diamond in a loop-gap microwave resonator and thermally connected the copper housing to the mixing chamber plate of a dilution refrigerator. The plate was at 13 mK (0.013 K), extremely close to absolute zero. The resonator confines microwaves of a specific frequency and makes them interact strongly with the electron spins in the diamond.
In the experiment, a static magnetic field of 232.15 mT was applied along the diamond's [001] crystal axis, and the electron spins were excited with 6.501 GHz microwaves. This excitation microwave is called the "pump." The frequency of the signal to be amplified was set at 6.595 GHz. The link between these two frequencies is a phenomenon called "four-spin cross relaxation," in which energy is exchanged among four electron spins.
In this process, two spins associated with the central-frequency transition and one spin each associated with the lower- and higher-frequency transitions exchange energy. The spins differ in the time they take to return to equilibrium: about 1,030 seconds for the lower-frequency spins and about 1,650 seconds for the higher-frequency spins. This difference creates a "population inversion" on the higher-frequency side, where more spins occupy the higher energy level than the lower one.
When a microwave at the resonant frequency enters spins in population inversion, the excited spins release energy through stimulated emission. This adds photons with the same frequency and phase relationship as the incoming signal, amplifying it. While a typical parametric amplifier relies on nonlinear wave mixing, this maser obtains gain from the stimulated emission of electron spins.
The team also investigated the conditions under which amplification begins by measuring the signal reflected from the resonator while varying the pump power. At a pump power of −59 dBm the signal was attenuated, but above −58 dBm the gain turned positive. They also estimated the spin population inversion from the reflection coefficient and compared it with calculations based on rate equations.
The identity of the other, faster-relaxing spin system that produces the difference in relaxation times has not been determined. The authors cite neutral nitrogen-vacancy (NV⁰) centers and nickel-related defects as candidates.
Power Gain Above 1,000-Fold, Even for Strong Signals
The team confirmed a power gain of more than 30 dB for the 6.595 GHz microwave signal. A power gain of 30 dB means the input signal's power is multiplied by 1,000. With the pump power set to −39 dBm, the amplification bandwidth near the frequency of maximum gain was about 70 kHz.
In evaluating an amplifier, it matters not only how well it amplifies weak signals but also how far it keeps working normally as the input grows stronger. Amplifiers exhibit "saturation," in which gain falls once input power exceeds a certain level. The team therefore gradually increased the input signal and measured the "1 dB compression point," where gain drops 1 dB below its small-signal value.
| Test | Condition | Result |
|---|---|---|
| Small-signal amplification (Fig. 3b) | Pump power −39 dBm | Power gain above 30 dB near 6.595 GHz, bandwidth about 70 kHz |
| 1 dB compression point (Fig. 4c) | Gain 20 dB | Input about −85 dBm, output about −65 dBm |
| 1 dB compression point (Fig. 4c) | Gain 10 dB | Input about −73 dBm, output about −63 dBm |
In the compression-point measurements, the team bypassed the downstream amplifier and examined how gain changed as the signal fed directly into the maser was strengthened. Lowering the gain from 20 dB to 10 dB allowed the maser to accept stronger input signals, while the output power at the compression point stayed relatively close, at about −65 to −63 dBm. The result shows that the strength of input signals the device can handle can be adjusted through the gain setting.
In OIST's official announcement, Kubo said, "We were surprised that such large amplification could be obtained with such a small microwave pump power." The team presents the large gain obtained with relatively weak microwave excitation as a notable feature of the result.
The maser can also change the frequency it amplifies by adjusting the external magnetic field. In a separate experiment with the pump power set to −44 dBm and the gain to 23 dB, adjusting the field shifted the center frequency of the gain by more than 10 MHz. However, this 10 MHz is the range over which the center frequency can be moved, and differs from the bandwidth that can be amplified simultaneously in a single setting.
Added Noise as Low as 3.05 Quanta, Approaching the Quantum Limit
In reading out quantum devices, how much noise an amplifier adds to the signal is crucial. Even if a signal is greatly amplified, a large amount of added noise makes it difficult to accurately determine the state of a qubit. In this study, the team measured the noise added by the amplifier itself using a calibrated noise source that generates known noise by varying its temperature.
The team varied the noise source's temperature from about 0.2 to 5 K and measured the output noise power with the pump on and off. They corrected the results for wiring attenuation and insertion loss to obtain the added noise referred to the amplifier's input. Measurements were made at five gain levels (10, 12.5, 15, 17.5 and 20 dB), and the lowest added noise was 3.05 ± 0.23 quanta.
Here, a "quantum" is a unit of noise based on the energy of a single photon at the signal frequency. The minimum added noise corresponds to a noise temperature of about 0.96 K. This is a converted value expressing the amplifier's noise performance and differs from the 13 mK temperature of the refrigerator's mixing chamber plate.
Even an ideal high-gain amplifier that preserves the signal's phase information adds at least 0.5 quanta of noise because of quantum-mechanical constraints. The maser's 3.05 quanta exceeds this standard quantum limit by about 2.55 quanta. Although it does not reach the full quantum limit, it shows that a maser, which does not use superconducting elements, can achieve low-noise amplification close to that limit.
The team identifies insufficient spin population inversion as the main cause of the remaining noise. Spins at the higher energy level contribute to amplification, but spins remaining at the lower level absorb the signal. At a gain of 20 dB, the estimated inversion ratio was about 0.17; entering this value into the model gives an added noise of about 3.29 quanta, consistent with the measurement.
The team also calculated how much noise could be reduced by improving the spin relaxation rate and resonator loss. Raising the relaxation rate from 0.95 × 10⁻³ to 1.2 × 10⁻³ per second would reduce the added noise to 1.94 quanta, and reducing the resonator's internal loss as well is predicted to bring it down to 1.70 quanta. These are theoretical estimates of the effect of improving spin relaxation properties and resonator performance, not measured results.
Application to Semiconductor Spin Qubits and Remaining Challenges
The diamond maser stands out because it can amplify with low noise at cryogenic temperatures and also operate under a static magnetic field. Superconducting parametric amplifiers using Josephson junctions and similar elements have been widely used to read out quantum computers. Semiconductor spin qubits, however, require a magnetic field to manipulate electron spins, so the amplifier must also tolerate magnetic fields.
Because a maser does not use superconducting junctions, it offers a new option for such conditions. A particular envisioned use is as the first-stage amplifier inside the refrigerator, amplifying the faint microwave signals returning from a quantum device. The team also cites electron spin resonance spectroscopy, nuclear magnetic resonance (NMR) spectroscopy and searches for axions, a dark matter candidate, as possible applications.
Practical use, however, will require a wider amplification bandwidth. The bandwidth of about 70 kHz under conditions giving more than 30 dB of gain could be a constraint for fast readout of multiple qubits. The insertion loss before the signal reaches the maser and the power required for the pump also need to be reduced. The team believes performance can be improved by optimizing the spin density and resonator structure, as well as by using different spin systems and materials.
The experiment used a device incorporating a single synthetic diamond crystal containing P1 centers. The paper's data and analysis code have been made public, but performance variation among different crystals and reproducibility by independent research teams have not been confirmed. Readout experiments connecting an actual semiconductor spin qubit have also not been carried out, so how accurately qubit states can be distinguished remains to be verified.
What the team has demonstrated is that a diamond maser operating in a magnetic field can combine power amplification of more than 1,000-fold with low-noise performance close to the quantum limit. By improving bandwidth and insertion loss and confirming readout performance with actual qubits, researchers will be able to evaluate its practicality as a technology complementing existing superconducting amplifiers.